ITEM NO.: CN61-MTG-5000 (suprised&big discount item,please contact us for the price)
Available in MTG-500L,MTG-500,MTG-1000,MTG-3000,MTG-4000A and MTG-5000
TYMC multifunction timegrapher MTG-5000 (TCXO and TYAPS)
The watch timing machine TYMC multifunction timegrapher MTG-5000 is the state-of-the-art top model for professional use.
With a high resolution 7 "color TFT display, the TYAPS signal processing unit, a horizontally divisible screen, a resolution of 0.2 s / d for rate, a highly stable temperature compensated TCXO time base and a long-term monitoring function for rate and amplitude, it is best equipped to meet all requirements of a professional watch service.
The TYAPS signal processing unit has a very powerful AGC (automatic gain control), it automatically adjusts the signal gain and noise filters side. Measuring is highly stable and reliable (especially the amplitude).
The TCXO timebase is temperature compensated and highly stable for exact measuring.
The programmed test mode:
The watch can be tested for a defined time in up to 6 positions (positions for measuring can be selected). After completion of the test program, the test results are displayed as a test report including beat rate, beat error and amplitude in each single position. It also renders the maximum difference of the beat rate and amplitude of the 6 positions.
The horizontally divisible screen:
To display double the length of the diagram at once the screen can be divided horizontally.
The long term monitoring mode:
Rate and amplitude can be measured for up to 32 hours and can be displayed numerically or graphically in a diagram.
Own measuring programs can be created, where parameters like division of the time line, measuring time and measuring position can be set.
The resolution:
In order to adjust watches very accurately, the graphic and numeric resolution can be switched from 1 b / d to 0.2 s / d.
Available with the optional printer (THERMO PRINT) the graphic and numeric results of all measurements and the result of the programmed test can be printed.
The stepper motor driven automatic microphon AUTOMIC-1 (available optionally) can be employed and connected to the programmed test mode and handle the long-term monitoring programs automatically.
functions:
measuring of beat rate [s / d]
measuring of beat error [ms]
automatic beat detection number (that can be set manually)
measurable beat numbers: 18.000, 19.800, 21.600, 25,200, 28,800 and 36.000 A / h
acoustic simulation watch beat (can be switched o?)
of measuring amplitude [°]
programmed 6-position test mode with test report
long-term monitoring mode for rate and amplitude
own test programs can be created for long term monitoring mode
horizontally divisible screen
graphic or numeric selectable resolution 0.2 s / d or 1 b / d
TYAPS signal processing unit which automatically controls the signal level and? Lter noise side
highly stable TCXO time base
thermal printer connection (THERMO PRINT available optionally)
connection for automatic microphone (AUTOMIC-1 available optionally)
technical specifications:
print datasheet:
Measuring facilities:
beat rate, beat error, beat number, amplitude, maximum difference of rate and amplitude of the tested positions
long-term monitoring (rate / amplitude)
Signal gain control:
The signal gain is completely automatically controlled by the TYAPS signal processing unit. It also filters noise and background noise side.
Beat numbers:
18.000, 19.800, 21.600, 25,200, 28,800 and 36.000 A / h
automatic detection or manual setting
Beat rate:
numeric display in s / d and diagram
Range: + / - 300 b / d
resolution: 1 s / d
accuracy: + / - 1 s / d
Beat error:
numeric display in s / d and diagram
range: 0.0 ms - 4.0 ms
resolution: 0.1 ms
accuracy: + / - 0.1 ms
Amplitude:
numeric display in degrees °
range: 90 ° - 350 °
resolution: 1 °
accuracy: + / - 3 °
lift angle adjustable from 30 ° to 60 ° resolution /: 0.1 °
6 POSITION programmed test mode:
selectable positions: 1-6
position by measuring time: 10-50 s
displayed test results:
beat rate, beat error, amplitude of each single position, maximum difference of beat rate and amplitude of the tested positions
Long-term monitoring mode:
rate and amplitude are measured for a defined time (up to 32 hours) and dispayed numerically or graphically.
Own measuring programs can be created
Display:
Backlit COLOR 7 "LCD display
resolution: 480 dots x 234 dots
dimensions: 153mm x 86mm
Diagram display:
Horizontal / 3 di? erent color modes
display is divisible horizontally, to display double the length of the diagram
Displayable length diagram:
480 dots horizontally / 960 dots horizontally divided with
screen
Time base:
TCXO (temperature compensated crystal oscillator)
stability: + / - 0.1 s / d
Case:
dimensions: 240 x 195 x 135 mm
weight: approximately 1.05 kilograms (without microphone)
Power supply:
internal power supply
90V - 240V AC 50-60Hz
Connectivities:
Direct thermal printer THERMAL PRINT (available optionally):
Printing of graphic or numeric results of the test
Printing the test result of the programmed test mode
Automatic microphon AUTOMIC-1 (available optionally):
stepper motor driven automatic microphone.