Item No.:CN61-MTG-3000
TYMC multifunction timegrapher MTG-3000
The watch timing machine TYMC multifunction timegrapher MTG-3000 is a semi-professional model, offering various functions to analyze a mechanical watch movement.
This model features a big, high resolution backlit LCD screen with 4 different display modes. It measures beat rate,beat error, beat number and amplitude.
It stores 2048 beats and offers a "pause" and "SHIFT" function to pause and view the previous measuring 2048 beats.
Furthermore this model comes up with a programmed test mode:
The watch can be tested for a defined time in up to 6 positions (positions for measuring can be selected). After comple --
tion of the test program, the test results are displayed as a test report including beat rate, beat error and amplitude
in each single position. It also renders the maximum difference of the beat rate and amplitude of the 6 positions.
Available with the optional printer (THERMO PRINT) the graphic and numeric results of all measurements and the result of the programmed test can be printed.
functions:
measuring of beat rate [s / d]
measuring of beat error [ms]
automatic beat detection number (that can be set manually)
measurable beat numbers: 18.000, 19.800, 21.600, 25,200, 28,800 and 36.000 A / h
acoustic simulation watch beat (can be switched off)
of measuring amplitude [°]
programmed 6-position test mode with test report
2048 beats stores
"PAUSE" and "SHIFT" function to stop measuring and view the previous beats 2048
thermal printer connection (THERMO PRINT available optionally)
connection for automatic microphone (AUTOMIC-1 available optionally)
technical specificatioprint:
Measuring facilities
beat rate, beat error, beat number, amplitude
Signal gain control:
The basic gain of the input signal is adjusted automatically.
The level can also be manually adjusted for movements with very strong or weak signal
Beat numbers:
18.000, 19.800, 21.600, 25,200, 28,800 and 36.000 A / h
automatic detection or manual setting
Beat rate:
numeric display in s / d and diagram
Range: + / - 300 b / d
resolution: 1 s / d
accuracy: + / - 1 s / d
Beat error:
numeric display in s / d and diagram
range: 0.0 ms - 4.0 ms
resolution: 0.1 ms
accuracy: + / - 0.1 ms
Amplitude:
numeric display in degrees °
range: 90 ° - 350 °
resolution: 1 °
accuracy: + / - 3 °
lift angle adjustable form 30 ° to 60 ° resolution /: 0.1 °
6 POSITION programmed test mode:
selectable positions: 1-6
position by measuring time: 10-50 s
displayed test results:
beat rate, beat error, amplitude of each single position,
maximum difference of beat rate and amplitude within the tested positions
Display:
backlit 5.6 "LC display
resolution: 320 dots x 240 dots
Diagram display:
horizontal pushing / extending horizontal / vertical pushing /
extending vertically
Displayable length diagram:
320 dots horizontal / 240 vertical dots
"Pause" function to stop the measuring and view the
previous 2048 Stored beats.
Time base:
XO
stability: + / - 0.3 s / d
Case:
dimensions: 240 x 160 x 100 mm
weight: about 0.8 kilograms (without power supply andmicrophone)
Power supply:
external power supply
90V - 240V AC 50-60Hz
Connectivities:
Direct thermal printer THERMAL PRINT (available optionally):
Printing of graphic or numeric results of themeasuring
Printing the test result of the programmed test mode
Automatic microphon AUTOMIC-1 (available optionally):
stepper motor driven automatic microphone