Connection for automatic microphone (AUTOMIC-1 available optionally)
technical specifications:
print datasheet:
Measuring facilities:
beat rate, beat error, beat number, amplitude
Signal gain control:
The signal gain is completely automatically controlled
TYAPS by the signal processing unit. It also filters side
noise and background noise.
Beat numbers:
18.000, 19.800, 21.600, 25,200, 28,800 and 36.000 A / h
automatic detection or manual setting
Beat rate:
numeric display in s / d and diagram
Range: + / - 300 b / d
resolution: 1 s / d
accuracy: + / - 1 s / d
Beat error:
numeric display in s / d and diagram
range: 0.0 ms - 4.0 ms
resolution: 0.1 ms
accuracy: + / - 0.1 ms
Amplitude:
numeric display in degrees °
range: 90 ° - 350 °
resolution: 1 °
accuracy: + / - 3 °
lift angle adjustable form 30 ° to 60 ° resolution /: 0.1 °
6 POSITION programmed test mode:
selectable positions: 1-6
position by measuring time: 10-50 s
displayed test results:
beat rate, beat error, amplitude of each single position,
maximum difference of beat rate and amplitude within the tested positions
Display:
Backlit COLOR 7 "LCD display
resolution: 480 dots x 234 dots
dimensions: 153mm x 86mm
Diagram display:
Horizontal / different color modes 5
Displayable length diagram:
480 dots horizontally
"PAUSE" function to stop the measuring and view the previous 720 stored beats.
Time base (PRO version):
TCXO (temperature compensated crystal oscillator)
stability: + / - 0.1 s / d
Case:
dimensions: 260 x 170 x 115 mm
weight: about 0.8 kilograms (without power supply and microphone)
Power supply:
external power supply
90V - 240V AC 50-60Hz
Connectivities:
Direct thermal printer THERMAL PRINT (available optionally):
Printing of graphic or numeric results of the measuring
Printing the test result of the programmed test mode
Automatic microphon AUTOMIC-1 (available optionally):
stepper motor driven automatic microphone.